Click here to watch Tutorial Videos >

Advanced Machine & Engineering Has Reasons to Breathe Easy



Stotz USA, LLC, is a leader in air gaging technology, products and quality gaging system integration. According to Stotz President Chris Koehn, Stotz has achieved that goal by a variety of means, not the least of which has been the loyalty of good customers, who appreciate the value Stotz products brings to theirs. One of those customers is also a longtime friend of Koehn's and he can say that with complete honesty, because he worked there, long ago. 

 

Advanced Machine & Engineering (AME) is a leader in high-quality machine tool spindle interface components. As part of the Goellner, Inc. Group, AME enjoys a reputation throughout the machine tool industry for manufacturing the finest power drawbars, spindle shafts, guide bushings, locknuts, hydraulic sleeves, expansion gibs and more. AME components, through its own branded products and those of its brother companies such as OTT Jakob, Spieth and Tschudin & Heid, as well as their "other brother" Hennig, itself a leader in chip conveyor and machine protection systems, are found on nearly every major machine tool brand.

 

AME was a customer of Stotz before Chris Koehn ever came to work at the air gaging company. Today, these two market leaders maintain a great working relationship, for all the right reasons. AME demands the highest level of quality in their machining and finishing departments and Stotz air gaging systems facilitate the accomplishment of that goal, every day, according to AME Service Manager, Greg Hobbs. "Air gaging is the only technology we've found that's accurate enough to check the machine tooling and especially the spindle tapers we produce here. That's a fact. In the past, we'd use hard gages and we still use them, but only for certain OD checks. We'd blue up the tapers, insert them, give them a good twist and do our inspections. Way too much inconsistency. Today, with sophisticated HSK tooling, this method is too hit or miss to be reliable. Air gaging provides dead stops on the test stand and the documentation is unbeatable for validation on the straightness, surface finish and taper angles. Plus, the Stotz system allows us to upload all the data on every part, so we have our favorite word...documentation...for every part we produce."

 

Hobbs also commented on the user-friendliness of the Stotz air column. When the program is first input into the column for a part in the AME grinding department, for example, the Stotz column essentially becomes a PLC, providing hard data via the Ethernet connections to the host data base. In this manner, every parameter of every part is documented and recorded. In a classic example of the law of unintended consequences, this process is not only used on the parts run, it's also used for calibrating the AME machines, in a predictive maintenance function. 

 

At AME, various testing of machined spindle interface and other components is performed both at the machines in the grinding department, in a temperature-controlled 72-degrees environment, plus in the company's totally environment-controlled in-house testing department, supervised by the company's Director of Quality, Brad Patterson. He confirmed Greg Hobbs' observation that numerous other technologies have been investigated over the years for quality checking at AME and that air gaging has been found to be the best and most reliable for this company's applications, particularly ID dimensions and configuration. Patterson also observed, "The sophistication of the Stotz air column is unmatched in the industry. We get all the data required and we get it in exactly the fashion needed to support our customers. Repeatable results and elimination of error, every time. Plus, the set-up is much faster than on our laser mics, which can't be used for ID measurement." Patterson further noted that the replacement of the bluing technique, one he termed a "black art," with air gaging has brought and keeps AME up to the most current industry standards for quality evaluation. 

 

The typical Stotz air column found here is the Model MSG, with four pneumatic channels or ten LVDT channels operating simultaneously, pneumatic length measuring, user specific programming up to 18 programs per column, full statistical analysis and full data transfer capability within the host network. All info is fed into the AME host computer by serial number, so any job can be quickly retrieved, while historical records on any part produced can be easily called up for evaluation, deviation claims or to dovetail with a customer's internal quality protocols. 

 

Typically, as AME's Grinding Supervisor, Sam Schubert, explains, the finished product will rest for 24 hours of soaking, allowing the diameters to normalize. Though statistically predictable for most metal materials, thermal expansion can cause off-normal readings to occur. For checking certain bearing journals or spindle shafts, snap gages are set to accommodate size measurements down to the twenty millionths (0.000020") range. The acceptable diameter tolerances for most AME products measured are in the 1-2 tenths (0.0001-0.0002") range.

 

In cases where new masters are made for setting control values, those values are preset offline and programmed into the air column's software, according to Greg Hobbs. Stotz typically performs this function for the customer in a remote manner over the Internet, through a proprietary IP address. 

 

Among the products finished in this grinding department are CAT/ISO 40 taper spindles, HSK test arbors, HSK grind quills, HSK steep taper milling tools and more. Often, older and worn spindle shafts are reverse engineered by AME for retrofits and remans. Even in these cases, air gaging is used to evaluate the finish process on the ID taper, as this technology is easily adapted to such applications, according to AME personnel. 

 

Sam Schubert expanded on the use of Stotz air gaging at AME: "We have a full and very expensive inventory of hard gages with state-of-the-art indicators attached. But the air gages can do so much more. We use them for set-up on the grinding machines and they save us hours, every week. When you run the number of jobs we do here, that translates into substantial, additional work product and therefore more revenue for the company. In terms of reliability, some of the Stotz air gages we run here have been at AME since we began using the technology, nearly ten years ago now." Schubert also noted the air gaging set-ups on the grinders dramatically reduce the time to first part in his department's operation.

 

On one major spindle shaft project for an Asian machine tool builder, who was looking for a local source of supply in America, Schubert notes, AME was confronted with an unusually large quantity run, where tool degradation during the run would normally impact the production at some point. After an initial batch was produced, the machine builder claimed that everything but the taper was satisfactory. Quite surprised by this claim, AME checked all the documentation and determined that the customer's test unit was actually out of spec, in a case where the error was repeated consistently and thus overlooked. In the end, the AME products were deemed better than perfect, in that instance.

 

"The documentation we can produce from the air gaging procedure is like a birth certificate on every unit we make," said Schubert. "All our spindle shafts for customers, for example, can be viewed as a series of genetically identical twins to each other and we're providing the documentation of their DNA."

 

Schubert said that AME is now purchasing air gaging fixtures for all new customer applications. This quality spindle interface manufacturer aims to "keep breathing easy" in process and product validation as a result.

 

Authored by Stotz USA and Harold Goellner, VP at AME

 

 

      For more information 

                 contact:

 

      Chris Koehn, President

      Stotz USA, LLC

      773 West Lincoln Street

      Suite 204

      Freeport, IL 61032

      815-297-1805

      Fax: 815-297-8274

      chris@stotz-usa.com

      www.stotz-usa.com

 

    Harold Goellner, VP

      AME

      2500 Latham Street

      Rockford, IL 61103

      815-962-6076 ext. 277

      Fax: 815-962-6483

      info@ame.com

      www.ame.com

 

 

 

 

  

 

 

 

 

 

 

 

Stotz MRG air column display all values of surface finish, taper angle, straightness.

(front row) HSK 40 grind quill, (back row) ANSI B 5.50 40 taper balance plug.

HSK 125 spindle shaft ID taper check.

 

 

 

 

 

 

 

 

< back